Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

770022003 | F677TSVR XP CAT6

  • Available in:
  • Asia
  • Australia/New Zealand
  • EMEA
  • Latin America
  • North America

F677TSVR XP w/ Category 6 Twisted Pair, Sidecar Cable, Riser, Black jacket, 1000 ft (305 m) reel

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Product classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Portfolio CommScope®
Product Type Hybrid cable, coax and twisted pair

Dimensions, Twisted Pair

Diameter Over Conductor 0.023 in per 1 strand
Diameter Over Dielectric 0.996 mm | 0.0392 in
Diameter Over Dielectric Tolerance ±0.003 in
Diameter Over Jacket 6.35 mm | 0.25 in
Jacket Thickness 0.635 mm | 0.025 in
Jacket Thickness, minimum spot 0.406 mm | 0.016 in

General Specifications

ANSI/TIA Category 6
Cable Type Hybrid
Center Conductor Type Solid
Construction Type Non-armored
Jacket Color Black

Dimensions

Overall Cable Width 14.3 mm | 0.563 in
Cable Length 304.8 m | 1000 ft
Diameter Over Center Conductor Tolerance ±0.0004 in
Diameter Over Center Conductor, specific 0.0403 in per 1 strand
Diameter Over Conductor, singles, specific 0.0254 in per 1 strand
Diameter Over Dielectric 4.572 mm | 0.18 in
Diameter Over Dielectric Tolerance ±0.004 in
Diameter Over Outer Shield (Braid) 5.385 mm | 0.212 in
Center Conductor Gauge 18 AWG
Inner Shield (Braid) Gauge 34 AWG

Dimensions, Coaxial

Jacket Thickness 0.762 mm | 0.03 in
Jacket Thickness, minimum spot 0.457 mm | 0.018 in
Diameter Over Jacket 7.061 mm | 0.278 in
Diameter Over Jacket Tolerance ±0.008 in

Electrical Specifications

Capacitance 52.493 pF/m | 16 pF/ft
Characteristic Impedance 75 ohm
Characteristic Impedance Tolerance ±3 ohm
Conductor dc Resistance 21.325 ohms/km | 6.5 ohms/kft
Dielectric Strength, conductor to shield 2500 Vdc
Jacket Spark Test Voltage 2500 Vac
Nominal Velocity of Propagation (NVP) 82 %
Shield dc Resistance 16.076 ohms/km | 4.9 ohms/kft
Structural Return Loss 15 dB @ 5–2200 MHz
Structural Return Loss Test Method 100% Swept Tested

Material Specifications

Center Conductor Material Copper-clad steel wire
Conductor Material Bare copper
Dielectric Material Foam PE
Jacket Material PVC
Inner Shield (Braid) Coverage 77 %
Inner Shield (Braid) Material Aluminum
Inner Shield (Tape) Material Aluminum/Poly, bonded
Outer Shield (Tape) Material Aluminum/Poly, non-bonded

Mechanical Specifications

Minimum Bend Radius, loaded, times 20 times
Minimum Bend Radius, unloaded, times 10 times

Environmental Specifications

Installation temperature -18 °C to +60 °C (-0.4 °F to +140 °F)
Operating Temperature -40 °C to +75 °C (-40 °F to +167 °F)
Environmental Space Non-plenum
Temperature Rating, UL 60 °C | 140 °F
Flame Test Method CMR
Safety Standard ETL | cETL

Packaging and Weights

Cable weight 89.29 kg/km | 60 lb/kft
Packaging Type Reel

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Portfolio CommScope®
Product Type Hybrid cable, coax and twisted pair

Dimensions, Twisted Pair

Diameter Over Conductor 0.023 in per 1 strand
Diameter Over Dielectric 0.996 mm | 0.0392 in
Diameter Over Dielectric Tolerance ±0.003 in
Diameter Over Jacket 6.35 mm | 0.25 in
Jacket Thickness 0.635 mm | 0.025 in
Jacket Thickness, minimum spot 0.406 mm | 0.016 in

General Specifications

ANSI/TIA Category 6
Cable Type Hybrid
Center Conductor Type Solid
Construction Type Non-armored
Jacket Color Black

Dimensions

Overall Cable Width 14.3 mm | 0.563 in
Cable Length 304.8 m | 1000 ft
Diameter Over Center Conductor Tolerance ±0.0004 in
Diameter Over Center Conductor, specific 0.0403 in per 1 strand
Diameter Over Conductor, singles, specific 0.0254 in per 1 strand
Diameter Over Dielectric 4.572 mm | 0.18 in
Diameter Over Dielectric Tolerance ±0.004 in
Diameter Over Outer Shield (Braid) 5.385 mm | 0.212 in
Center Conductor Gauge 18 AWG
Inner Shield (Braid) Gauge 34 AWG

Dimensions, Coaxial

Jacket Thickness 0.762 mm | 0.03 in
Jacket Thickness, minimum spot 0.457 mm | 0.018 in
Diameter Over Jacket 7.061 mm | 0.278 in
Diameter Over Jacket Tolerance ±0.008 in

Electrical Specifications

Capacitance 52.493 pF/m | 16 pF/ft
Characteristic Impedance 75 ohm
Characteristic Impedance Tolerance ±3 ohm
Conductor dc Resistance 21.325 ohms/km | 6.5 ohms/kft
Dielectric Strength, conductor to shield 2500 Vdc
Jacket Spark Test Voltage 2500 Vac
Nominal Velocity of Propagation (NVP) 82 %
Shield dc Resistance 16.076 ohms/km | 4.9 ohms/kft
Structural Return Loss 15 dB @ 5–2200 MHz
Structural Return Loss Test Method 100% Swept Tested

Material Specifications

Center Conductor Material Copper-clad steel wire
Conductor Material Bare copper
Dielectric Material Foam PE
Jacket Material PVC
Inner Shield (Braid) Coverage 77 %
Inner Shield (Braid) Material Aluminum
Inner Shield (Tape) Material Aluminum/Poly, bonded
Outer Shield (Tape) Material Aluminum/Poly, non-bonded

Mechanical Specifications

Minimum Bend Radius, loaded, times 20 times
Minimum Bend Radius, unloaded, times 10 times

Environmental Specifications

Installation temperature -18 °C to +60 °C (-0.4 °F to +140 °F)
Operating Temperature -40 °C to +75 °C (-40 °F to +167 °F)
Environmental Space Non-plenum
Temperature Rating, UL 60 °C | 140 °F
Flame Test Method CMR
Safety Standard ETL | cETL

Packaging and Weights

Cable weight 89.29 kg/km | 60 lb/kft
Packaging Type Reel

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Building Information Modeling (BIM) Objects

Building Information Modeling (BIM) Objects