Base Product: O-LD
96 Core OS2 Outdoor Mini Loose Tube - Double Jacket
Regional Availability | Asia | Australia/New Zealand |
Portfolio | CommScope® |
Product Type | Fiber OSP cable |
Product Series | O-LN |
Attenuation, maximum | 0.21 dB/km @ 1,550 nm | 0.35 dB/km @ 1,310 nm |
Cable Type | Stranded loose tube |
Construction Type | Non-armored |
Jacket Color | Blue |
Subunit, quantity | 8 |
Fibers per Subunit, quantity | 12 |
Buffer Tube/Subunit Diameter | 1.55 mm | 0.061 in |
Diameter Over Jacket | 7.4 mm | 0.291 in |
Click on image to enlarge. |
Jacket Material | Nylon | PE |
Minimum Bend Radius, loaded | 220 mm | 8.661 in |
Minimum Bend Radius, unloaded | 110 mm | 4.331 in |
Tensile Load, short term, maximum | 2000 N | 449.618 lbf |
Compression | 20 N/mm | 114.203 lb/in |
Compression Test Method | IEC 60794-1-21 E3 |
Flex | 25 cycles |
Impact | 1 N-m | 8.851 in lb |
Impact Test Method | IEC 60794-1-21 E4 |
Strain | See long and short term tensile loads |
Strain Test Method | IEC 60794-1-21 E1 |
Twist | 10 cycles |
Twist Test Method | IEC 60794-1-21 E7 |
Installation temperature | 0 °C to +50 °C (+32 °F to +122 °F) |
Operating Temperature | 0 °C to +50 °C (+32 °F to +122 °F) |
Storage Temperature | -20 °C to +70 °C (-4 °F to +158 °F) |
Environmental Space | Buried | Underground (duct) |
Jacket UV Resistance | UV stabilized |
Water Penetration | 24 h |
Water Penetration Test Method | IEC 60794-1 F5C |
Temperature Cycle | -10 °C to +60 °C (+14 °F to +140 °F) |
Temperature Cycle Test Method | IEC 60794-1-22 F1 |
Cable weight | 49 kg/km | 32.927 lb/kft |
Regional Availability | Asia | Australia/New Zealand |
Portfolio | CommScope® |
Product Type | Fiber OSP cable |
Product Series | O-LN |
Attenuation, maximum | 0.21 dB/km @ 1,550 nm | 0.35 dB/km @ 1,310 nm |
Cable Type | Stranded loose tube |
Construction Type | Non-armored |
Jacket Color | Blue |
Subunit, quantity | 8 |
Fibers per Subunit, quantity | 12 |
Buffer Tube/Subunit Diameter | 1.55 mm | 0.061 in |
Diameter Over Jacket | 7.4 mm | 0.291 in |
Jacket Material | Nylon | PE |
Minimum Bend Radius, loaded | 220 mm | 8.661 in |
Minimum Bend Radius, unloaded | 110 mm | 4.331 in |
Tensile Load, short term, maximum | 2000 N | 449.618 lbf |
Compression | 20 N/mm | 114.203 lb/in |
Compression Test Method | IEC 60794-1-21 E3 |
Flex | 25 cycles |
Impact | 1 N-m | 8.851 in lb |
Impact Test Method | IEC 60794-1-21 E4 |
Strain | See long and short term tensile loads |
Strain Test Method | IEC 60794-1-21 E1 |
Twist | 10 cycles |
Twist Test Method | IEC 60794-1-21 E7 |
Installation temperature | 0 °C to +50 °C (+32 °F to +122 °F) |
Operating Temperature | 0 °C to +50 °C (+32 °F to +122 °F) |
Storage Temperature | -20 °C to +70 °C (-4 °F to +158 °F) |
Environmental Space | Buried | Underground (duct) |
Jacket UV Resistance | UV stabilized |
Water Penetration | 24 h |
Water Penetration Test Method | IEC 60794-1 F5C |
Temperature Cycle | -10 °C to +60 °C (+14 °F to +140 °F) |
Temperature Cycle Test Method | IEC 60794-1-22 F1 |
Cable weight | 49 kg/km | 32.927 lb/kft |
Click on image to enlarge. |