Base Product: C-DN
Indoor/Outdoor Fiber Optic Drop cable, 1 Fiber G657 A2 0.9mm tight buffer. Breaking load Max 2000N. Suitable for installation under overhead power lines ≤11kV, vertical clearance ≥1.8m.
| Regional Availability | Asia | Australia/New Zealand | EMEA | North America | 
| Portfolio | CommScope® | 
| Product Type | Fiber indoor/outdoor cable | 
| Cable Type | Drop | Tight buffer | 
| Construction Type | Non-armored | All Dielectric | 
| Subunit Type | Gel-free | 
| Jacket Marking Method | Inkjet | 
| Jacket Marking Text | COMMSCOPE GB OPTICAL CABLE 810010113/DB 1x G657A2 SM LSZH [DOM] [SERIAL NUMBER] [METER MARK] | 
| Subunit, quantity | 1 | 
| Fibers per Subunit, quantity | 1 | 
| Cable Length | 1000 m | 3280.84 ft | 
| Buffer Tube/Subunit Diameter | 0.9 mm | 0.035 in | 
| Diameter Over Jacket | 3 mm | 0.118 in | 
| Click on image to enlarge. | 
| Jacket Material | Low Smoke Zero Halogen (LSZH) | 
| Minimum Bend Radius, loaded | 30 mm | 1.181 in | 
| Tensile Load, long term, maximum | 300 N | 67.443 lbf | 
| Tensile Load, short term, maximum | 620 N | 139.382 lbf | 
| Compression | 20 N/mm | 114.203 lb/in | 
| Compression Test Method | IEC 60794-1 E3 | 
| Impact | 2 N-m | 17.701 in lb | 
| Impact Test Method | IEC 60794-1 E4 | 
| Strain | See long and short term tensile loads | 
| Strain Test Method | IEC 60794-1 E1 | 
| Twist | 10 cycles | 
| Twist Test Method | IEC 60794-1 E7 | 
| Installation temperature | -10 °C to +60 °C (+14 °F to +140 °F) | 
| Operating Temperature | -30 °C to +65 °C (-22 °F to +149 °F) | 
| Storage Temperature | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Cable Qualification Standards | IEC 60794-1-2 | 
| EN50575 CPR Cable EuroClass Fire Performance | Dca | 
| EN50575 CPR Cable EuroClass Smoke Rating | s1a | 
| EN50575 CPR Cable EuroClass Droplets Rating | d0 | 
| EN50575 CPR Cable EuroClass Acidity Rating | a2 | 
| Environmental Space | Aerial | Drop | Ducted | Indoor/Outdoor | 
| Flame Test Listing | EN 50399 | 
| Flame Test Method | IEC 60332-1-2 | IEC 60754-2 | IEC 61034-2 | 
| Jacket UV Resistance | UV stabilized | 
| Water Penetration | 24 h | 
| Water Penetration Test Method | IEC 60794-1 F5 | 
| Temperature Cycle | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Temperature Cycle Test Method | IEC 60794-1-22 F1 | 
| Cable weight | 8.7 kg/km | 5.846 lb/kft | 
| Regional Availability | Asia | Australia/New Zealand | EMEA | North America | 
| Portfolio | CommScope® | 
| Product Type | Fiber indoor/outdoor cable | 
| Cable Type | Drop | Tight buffer | 
| Construction Type | Non-armored | All Dielectric | 
| Subunit Type | Gel-free | 
| Jacket Marking Method | Inkjet | 
| Jacket Marking Text | COMMSCOPE GB OPTICAL CABLE 810010113/DB 1x G657A2 SM LSZH [DOM] [SERIAL NUMBER] [METER MARK] | 
| Subunit, quantity | 1 | 
| Fibers per Subunit, quantity | 1 | 
| Cable Length | 1000 m | 3280.84 ft | 
| Buffer Tube/Subunit Diameter | 0.9 mm | 0.035 in | 
| Diameter Over Jacket | 3 mm | 0.118 in | 
| Jacket Material | Low Smoke Zero Halogen (LSZH) | 
| Minimum Bend Radius, loaded | 30 mm | 1.181 in | 
| Tensile Load, long term, maximum | 300 N | 67.443 lbf | 
| Tensile Load, short term, maximum | 620 N | 139.382 lbf | 
| Compression | 20 N/mm | 114.203 lb/in | 
| Compression Test Method | IEC 60794-1 E3 | 
| Impact | 2 N-m | 17.701 in lb | 
| Impact Test Method | IEC 60794-1 E4 | 
| Strain | See long and short term tensile loads | 
| Strain Test Method | IEC 60794-1 E1 | 
| Twist | 10 cycles | 
| Twist Test Method | IEC 60794-1 E7 | 
| Installation temperature | -10 °C to +60 °C (+14 °F to +140 °F) | 
| Operating Temperature | -30 °C to +65 °C (-22 °F to +149 °F) | 
| Storage Temperature | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Cable Qualification Standards | IEC 60794-1-2 | 
| EN50575 CPR Cable EuroClass Fire Performance | Dca | 
| EN50575 CPR Cable EuroClass Smoke Rating | s1a | 
| EN50575 CPR Cable EuroClass Droplets Rating | d0 | 
| EN50575 CPR Cable EuroClass Acidity Rating | a2 | 
| Environmental Space | Aerial | Drop | Ducted | Indoor/Outdoor | 
| Flame Test Listing | EN 50399 | 
| Flame Test Method | IEC 60332-1-2 | IEC 60754-2 | IEC 61034-2 | 
| Jacket UV Resistance | UV stabilized | 
| Water Penetration | 24 h | 
| Water Penetration Test Method | IEC 60794-1 F5 | 
| Temperature Cycle | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Temperature Cycle Test Method | IEC 60794-1-22 F1 | 
| Cable weight | 8.7 kg/km | 5.846 lb/kft | 
| Click on image to enlarge. |