Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

760252292 | L-002-ZT-5K-M15OR

Base Product: L-ZT

  • Available in:
  • Asia
  • Australia/New Zealand
  • Latin America
  • Middle East/Africa
  • North America

Fiber indoor cable, TeraSPEED® Plenum Light Duty Interconnect Cordage, 2 fiber, Singlemode G.652.D and G.657.A1, Meters jacket marking, Orange jacket color

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Product classification

Regional Availability Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America
Portfolio CommScope®
Product Type Fiber indoor cable
Product Series L-ZT

General Specifications

Cable Type MPO trunk cable
Construction Type Non-armored
Subunit Type Gel-free
Jacket Marking Method Inkjet
Jacket Marking Text COMMSCOPE GB OPTICAL CABLE 760252292 2x50/125 OM4 LSZH [Serial NUMBER] [METRE MARK]

Dimensions

Diameter Over Jacket 1.5 mm | 0.059 in

Representative Image

Click on image to enlarge.

Mechanical Specifications

Minimum Bend Radius, loaded 38 mm | 1.496 in
Minimum Bend Radius, unloaded 16 mm | 0.63 in
Tensile Load, long term, maximum 67 N | 15.062 lbf
Tensile Load, short term, maximum 222 N | 49.908 lbf
Compression 4 N/mm | 22.841 lb/in
Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex 300 cycles
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact 0.74 N-m | 6.55 in lb
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7
Vertical Rise, maximum 500 m | 1640.42 ft

Environmental Specifications

Installation temperature 0 °C to +60 °C (-32 °F to +140 °F)
Operating Temperature -4 °C to +60 °C (-14 °F to +140 °F)
Storage Temperature -5 °C to +50 °C (+23 °F to +122 °F)
Cable Qualification Standards ANSI/ICEA S-83-596 | Telcordia GR-409
Environmental Space Plenum
Flame Test Listing NEC OFNP (ETL) and c(ETL)
Flame Test Method NFPA 262
Jacket UV Resistance ASTM G154 Cycle 1, for 720 hours
Heat Age 0 °C to +85 °C (+32 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend 0 °C to +70 °C (+32 °F to +158 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle 0 °C to +70 °C (+32 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1

Packaging and Weights

Cable weight 3.9 kg/km | 2.621 lb/kft

Product classification

Regional Availability Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America
Portfolio CommScope®
Product Type Fiber indoor cable
Product Series L-ZT

General Specifications

Cable Type MPO trunk cable
Construction Type Non-armored
Subunit Type Gel-free
Jacket Marking Method Inkjet
Jacket Marking Text COMMSCOPE GB OPTICAL CABLE 760252292 2x50/125 OM4 LSZH [Serial NUMBER] [METRE MARK]

Dimensions

Diameter Over Jacket 1.5 mm | 0.059 in

Mechanical Specifications

Minimum Bend Radius, loaded 38 mm | 1.496 in
Minimum Bend Radius, unloaded 16 mm | 0.63 in
Tensile Load, long term, maximum 67 N | 15.062 lbf
Tensile Load, short term, maximum 222 N | 49.908 lbf
Compression 4 N/mm | 22.841 lb/in
Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex 300 cycles
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact 0.74 N-m | 6.55 in lb
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7
Vertical Rise, maximum 500 m | 1640.42 ft

Environmental Specifications

Installation temperature 0 °C to +60 °C (-32 °F to +140 °F)
Operating Temperature -4 °C to +60 °C (-14 °F to +140 °F)
Storage Temperature -5 °C to +50 °C (+23 °F to +122 °F)
Cable Qualification Standards ANSI/ICEA S-83-596 | Telcordia GR-409
Environmental Space Plenum
Flame Test Listing NEC OFNP (ETL) and c(ETL)
Flame Test Method NFPA 262
Jacket UV Resistance ASTM G154 Cycle 1, for 720 hours
Heat Age 0 °C to +85 °C (+32 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend 0 °C to +70 °C (+32 °F to +158 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle 0 °C to +70 °C (+32 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1

Packaging and Weights

Cable weight 3.9 kg/km | 2.621 lb/kft
Click on image to enlarge.

Building Information Modeling (BIM) Objects

Building Information Modeling (BIM) Objects