CS67ZB Category 7A S/FTP Cable, low smoke zero halogen, white jacket, 8 pair count, 2 x 4 pairs in a duplex style configuration, 500 m (1640 ft) length, reel
| Regional Availability | EMEA | 
| Portfolio | NETCONNECT® | 
| Product Type | Twisted pair cable | 
| Product Number | CS67ZB | 
| ANSI/TIA Category | 7A | 
| Cable Component Type | Horizontal | 
| Conductor Type, singles | Solid | 
| Conductors, quantity | 16 | 
| Pairs, quantity | 8 | 
| Transmission Standards | CENELEC EN 50288-9-1 | IEC 61156-7 | 
| Cable Length | 500 m | 1640.42 ft | 
| Cable Length Tolerance | ±5% | 
| Diameter Over Jacket, nominal | 7.595 mm | 0.299 in | 
| Jacket Thickness | 0.635 mm | 0.025 in | 
| Conductor Gauge, singles | 22 AWG | 
| Click on image to enlarge. | 
| Coupling Attenuation | Type I | 
| dc Resistance Unbalance, maximum | 2 % | 
| dc Resistance, maximum | 6.51 ohms/100 m | 1.984 ohms/100 ft | 
| Mutual Capacitance at Frequency | 4.1 nF/100 m @ 1 kHz | 
| Nominal Velocity of Propagation (NVP) | 80 % | 
| Operating Frequency, maximum | 1200 MHz | 
| Operating Voltage, maximum | 80 V | 
| Conductor Material | Bare copper | 
| Insulation Material | Polyolefin | 
| Jacket Material | Low Smoke Zero Halogen (LSZH) | 
| Shield (Braid) Material | Tinned copper | 
| Shield (Tape) Material | Polyester/Aluminum shield | 
| Pulling Tension, maximum | 11.34 kg | 25 lb | 
| Installation temperature | 0 °C to +50 °C (+32 °F to +122 °F) | 
| Operating Temperature | -20 °C to +60 °C (-4 °F to +140 °F) | 
| Acid Gas Test Method | EN 50267-2-3 | 
| EN50575 CPR Cable EuroClass Smoke Rating | s1 | 
| EN50575 CPR Cable EuroClass Droplets Rating | d1 | 
| EN50575 CPR Cable EuroClass Acidity Rating | a1 | 
| Environmental Space | Low Smoke Zero Halogen (LSZH) | 
| Smoke Test Method | IEC 61034-2 | 
| Cable weight | 1353.038 kg/km | 909.2 lb/kft | 
| Agency | Classification | 
| CENELEC   | EN 50575 compliant, Declaration of Performance (DoP) available | 
| ISO 9001:2015 | Designed, manufactured and/or distributed under this quality management system | 
| Regional Availability | EMEA | 
| Portfolio | NETCONNECT® | 
| Product Type | Twisted pair cable | 
| Product Number | CS67ZB | 
| ANSI/TIA Category | 7A | 
| Cable Component Type | Horizontal | 
| Conductor Type, singles | Solid | 
| Conductors, quantity | 16 | 
| Pairs, quantity | 8 | 
| Transmission Standards | CENELEC EN 50288-9-1 | IEC 61156-7 | 
| Cable Length | 500 m | 1640.42 ft | 
| Cable Length Tolerance | ±5% | 
| Diameter Over Jacket, nominal | 7.595 mm | 0.299 in | 
| Jacket Thickness | 0.635 mm | 0.025 in | 
| Conductor Gauge, singles | 22 AWG | 
| Coupling Attenuation | Type I | 
| dc Resistance Unbalance, maximum | 2 % | 
| dc Resistance, maximum | 6.51 ohms/100 m | 1.984 ohms/100 ft | 
| Mutual Capacitance at Frequency | 4.1 nF/100 m @ 1 kHz | 
| Nominal Velocity of Propagation (NVP) | 80 % | 
| Operating Frequency, maximum | 1200 MHz | 
| Operating Voltage, maximum | 80 V | 
| Conductor Material | Bare copper | 
| Insulation Material | Polyolefin | 
| Jacket Material | Low Smoke Zero Halogen (LSZH) | 
| Shield (Braid) Material | Tinned copper | 
| Shield (Tape) Material | Polyester/Aluminum shield | 
| Pulling Tension, maximum | 11.34 kg | 25 lb | 
| Installation temperature | 0 °C to +50 °C (+32 °F to +122 °F) | 
| Operating Temperature | -20 °C to +60 °C (-4 °F to +140 °F) | 
| Acid Gas Test Method | EN 50267-2-3 | 
| EN50575 CPR Cable EuroClass Smoke Rating | s1 | 
| EN50575 CPR Cable EuroClass Droplets Rating | d1 | 
| EN50575 CPR Cable EuroClass Acidity Rating | a1 | 
| Environmental Space | Low Smoke Zero Halogen (LSZH) | 
| Smoke Test Method | IEC 61034-2 | 
| Cable weight | 1353.038 kg/km | 909.2 lb/kft | 
| Click on image to enlarge. | 
| Agency | Classification | 
| CENELEC   | EN 50575 compliant, Declaration of Performance (DoP) available | 
| ISO 9001:2015 | Designed, manufactured and/or distributed under this quality management system |